Page view 6
Rettig USA Inc. • 948 Hercules Drive, Colchester, VT 05446 • Phone: 800-698-9690 • Fax: 802-654-7022 • www.MysonInc.com
14"
15
1
2"
19
11
16"
WHISPA-E
DO NOT COVER
WARNING
IMMEDIATELY DISCONNECT
FROM THE MAINS
BEFORE REMOVING
THIS COVER
PLINTH HEATER WHISPA-E
VOLTS-120VAC. 60 HZ
AMPS-13
WATTS-1600
MADE IN THE U.K.
USE ONLY ON 20 AMPERE BRANCH CIRCUIT
MYSON
L
I
S
T
E
D
WHISPA E KICKSPACE HEATER DIMENSIONS
3
1
2"
Fan Unit... A highly efficient 110 cfm tangential
fan extends the full width of the heating
element, giving extremely quiet, trouble-free
operation. All units have aluminum fans,
sealed motor bearings, and permanently
lubricated bearings.
Controls... Units have a lighted fan switch to
indicate power “ON.” Heat is controlled using
a dual rocker switch — both switches “OFF”
for fan only, either switch “ON” for 800 Watts
(Low), and both switches “ON” for
1600 Watts (High). Each unit has a high
temperature limit switch to shut off power in
the event of excessive temperature resulting
from restricted airflow.
Construction... The chassis is manufactured
from zinc-coated painted steel. The grill
is hardened aluminum for strength
and durability.
Electrical connections... Wiring connections
are supplied through the rear of each unit.
Motor is 110V, 60Hz and is ETL listed. Dual
heating elements draw a total of 15 amps
on the high setting.
Front View
DO NOT COVER
WH E50 Electric Fan Convector
19
11
16"
Top View
8
7
8"
Electric Kickspace Heater from MYSON
WHISPA
TM
E50
L
I
S
T
E
D
WHISPA E50 ELECTRIC KICKSPACE HEATER SPECIFICATIONS — Engineered to be efficient.
Baseboard C.I. Radiators Weight Weight Dimensions
Model Settings v/Hz Watts BTUs/hr Amps (525 Btu/ft) (225 Btu/sq ft) Unit (lbs) Packed (lbs) H W D
WH E50 High 110V/60Hz 1600 5460 13.0 10.4 24.3 8.1 10 4" 19-11/16" 8-7/8"
Low 110V/60Hz 800 2731 6.5 5.2 12.1
Whispa E50 Electric Kickspace Fan Convector
Power/Fan Settings:
OFF ON
Indicated by red light.
Heater Settings:
OFF LOW (
Either Position
) HIGH
INSTALLATION DIMENSIONS
A Width 20"
B Height 4" (min.)
C Depth of 16"
Cabinet
D Base Shelf
Overhang 1"
C
Be sure to provide sufficient space around the
unit to allow for adequate air circulation.
A
B
L
CONTROLS
D
NOTE: For proper sizing, use the rating at Medium or Low speeds.
ISO 9002
L
I
S
T
E
D
7
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 15 16