Myson 15-10 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
B
W
6
1
/4"
3
3
/4"
2
9
/16"
Optional legs—provided with unit
Back panel
mounting holes
1
1
/2"
Controls... Units have a two speed
Boost/Normal fan switch and built-in
thermostat. All models have low-limit
thermostats which close at 109°F and
open at 91°F. Optional low temperature
thermostat is available.
Construction... The chassis is manufactured
from zinc coated steel with a baked
epoxy polyester. Fan assemblies have ball
bearings for longer life and quieter service.
Warranty... MYSON offers a full ten year
warranty on the heat exchanger and a full
three year warranty on the fan motor.
CSU FAN CONVECTOR SPECIFICATIONS — Engineered to be efficient.
Economical Fan Convector from MYSON
Side View
Bottom View
Top Vie w
3"
9
/16"
7
/8" conduit hole
1
9
/16"
1
9
/16"
Water connections
2"
Supply
Return
4
23
/32"
13
1
/4"
Air In
Air Out
Wall Side
W
CSU
TM
Front View
CSU Fan Convector
Rettig USA Inc. • 948 Hercules Drive, Colchester, VT 05446 • Phone: 800-698-9690 • Fax: 802-654-7022 • www.MysonInc.com
NOTE: For surface
or floor mounting
application only.
Flow Rate Fan Air Delivery
Model (gpm1) Speed (cfm)
2437 3226 4173 5195 6040 6852 7763 8659 9500 10341
1190 1954 2529 3165 3823 4481 5319 5973 6609 7245
1928 3886 4994 6102 7203 8715 10331 11947 14000 15053
1524 2484 3452 4418 5385 6352 7317 8282 9240 10198
4400 6481 8573 10665 12750 14838 16947 19027 21000 23235
2018 3461 4687 5751 6983 8260 9518 10813 12262 13771
CSU-10M 3.0 Boost 99
Normal 62
CSU-15M 3.0 Boost 91
Normal 66
CSU-23M 3.0 Boost 129
Normal 92
Entering water temperature (°F)
120 130 140 150 160 170 180 190 200 210
Friction
Flow Rate Fan Baseboard C.I. Radiators Dimensions Weight Weight Flow Rate Loss (head)
Model (gpm) Speed (525 Btu/ft) (225 Btu/sq ft) H W D Unit (lbs) Packed (lbs) (gpm) FT WG
CSU-10M 3.0 Boost/Normal 14.7 / 10.1 34.5 / 23.6 13-1/4" 5 -3/8" 4-28/32" 17 20 3.0 13.1
CSU-15M 3.0 Boost/Normal 19.6 / 13.9 45.0 / 32.5 13-1/4" 35-7/8" 4 -28/32" 22 25 3.0 9.4
CSU-23M 3.0 Boost/Normal 32.2 / 18.1 75.0 / 42.3 13-1/4" 41-3/8" 4-28/32" 28 31 3.0 6.4
CSU Fan Convectors Btu/hr Heat Output - entering air @ 65ºF
CSU Heat Comparison @ 180°F Water Temperature
DIMENSIONS
MODEL # W B
CSU-10M 21-3/8" 17-1/4"
CSU-15M 28-7/8" 24-7/8"
CSU-23M 41-3/8" 37-1/2"
13
ISO 9002
L
I
S
T
E
D
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16