Myson Kickspace 800 Operations Instructions Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
2. ELECTRICAL SUPPLY
Fig. 3.2 - Plinth opening (floor mounting) Fig. 3.3 - Plinth opening (plinth mounting)
WARNING: THIS APPLIANCE MUST BE EARTHED.
2.1 The Kickspace 800 is supplied fitted with a 2 metre 0.75 mm² cord.
2.2 A fused electrical spur with a switch having 3 mm separation on all poles must be provided in an easily
accessible position adjacent to the Kickspace, as shown in Fig. 2.2.
2.3 Room Thermostat - If a room thermostat is to be fitted, wire it at this stage. See wiring diagram on page 7.
2.4 Remote Control Switch - A Remote Control Switch is available as an accessory, and if required should be
wired at this stage.
Remote Controls kits for the Kickspace 500 and 600 are suitable for the Kickspace 800. Follow the
instructions supplied with the kit, connecting the cable supplied as follows:-
Yellow lead to spare side of terminal block position '1'
Brown lead to spare side of terminal block opposite position 'L'
Red lead to spare side of terminal block position '3'
Green/Yellow (Brass or Chrome switch only) connect to terminal block position '
'
Do not energize the electrical supply until the remaining stages of the installation have been completed.
ELECTRICAL SUPPLY - continued
Kickspace
Switched fused spur
3. PREPARATION
3.1 A clean and level floor area is required under
the cupboard base.
3.2 Floor mounting - The Kickspace is normally
fitted directly onto the floor. Four mounting feet
are fitted to the base of the unit.
Decide the position of the Kickspace, mark out
and cut the plinth to the dimensions as shown in
Fig. 3.2.
3.3 Plinth mounting - As an alternative to floor
mounting the unit may be fitted into the plinth.
For this application cut the plinth to the
dimensions as shown in Fig. 3.3.
A suitable support must be securely fitted to
the floor. The top of the support must be level
with the lower edge of the cut-out when fitted.
3.4 A minimum of 25 mm clear headroom is
required above the top of the Kickspace
when fitted.
Fig. 2.2 - Electrical supply
PREPARATION - continued
3.5 Flexible connection hoses with integral isolating valves are supplied to allow for easy installation and future
access for maintenance etc.
100 mm
575 mm
Base of cupboard
100 mm
575 mm
Page view 2
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments