Myson 15-10 User Manual

Browse online or download User Manual for Water heaters & boilers Myson 15-10. Whispa II pdf [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MYSON
Fan
Convector
Technical
Specifications
January 2006—Rev A
Whispa II
Whispa 50
Whispa E
Hi-Line
Lo-Line
Lo-Line HC
Slim-Line
CSU
B
o
o
s
t
O
f
f
N
or
mal
M
Y
S
O
N
B
o
o
s
t
O
ff
Normal
M
Y
S
O
N
B
o
o
s
t
O
f
f
N
o
r
m
a
l
M
Y
S
O
N
L
I
S
T
E
D
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - January 2006—Rev A

MYSONFanConvectorTechnicalSpecificationsJanuary 2006—Rev AWhispa IIWhispa 50Whispa EHi-LineLo-LineLo-Line HCSlim-LineCSUBoostOffNormalMYSONBoostOffNor

Page 2 - Hydronic Fan Convectors

MODEL UNIT WEIGHT# WEIGHT PACKEDFAN CONVECTOR COMPARISON @ 180°F WATER TEMPFRICTION LOSS(HEAD)UNIT WEIGHT (LBS)19-15 Boost/Med/Low 41/33/26 ft 95/77/

Page 3

Model Flow Fan Latent* — BTU/hr Sensible — BTU/hr# Rate Speed 25ºF 35ºF 45ºF 25ºF 35ºF 45ºFHC 19-15 3 gpm Boost 6,430 10,638 15,488 5,239 6,263 7,157M

Page 4 - Features:

Slim-Line Fan ConvectorISO 9002Side View6 11/16"3/4"2"3 1/4"6 7/8"5"1 7/8"1 3/8"Minimum spacerequired (floor t

Page 5 - Recessed Wall Heaters

BA61/4"33/4"29/16"Optional legs—provided with unitBack panelmounting holes11/2"Controls... Units have a two speed Boost/Normal fan

Page 6

12 Myson, Inc. • 800-698-9690 • www.MysonInc.comKickspace Fan Convector InstallationMYSON EZ-Hose Kit1. A kickspace heater must have a free flow of ai

Page 7 - Kickspace Heaters from MYSON

Myson, Inc. • 800-698-9690 • www.MysonInc.com 13Radiator and Fan Convector InstallationOptional Piping ArrangementsThe following drawings are general

Page 8

10M 260021 1/2006MYSON warrants the original purchaser that products manufacturedand/or supplied by them will be free from defects in materials and w

Page 9

Hydronic Fan ConvectorsFan Convectors are designed to provide heat in a minimum of space using forced convection. MYSON’s efficienttangential fan des

Page 10 - Fan Convector from MYSON

Myson, Inc. • 800-698-9690 • www.MysonInc.comFRICTION LOSS (HEAD)WH II 5000 1.0 / 3.0 0.13 / 1.20WH II 9000 1.0 / 3.0 0.40 / 2.77MODEL FLOW RATE FT W

Page 11 - ISO 9002

BoostOffNormalMYSONMYSON’s EZ-Hose kit is specifically designed for installation with MYSON FanConvectors. It allows the unit to be easily removed fr

Page 12 - Slim-Line

Controls... Units have a two-speedBoost/Off/Normal fan switch. For installations without a separatethermostat, all models have low-limitthermostats w

Page 13

ENTERING WATER TEMPERATURE (°F)110* 120* 130* 140 150 160 170 180 190 2001,995 2,473 2,957 3,447 3,941 4,440 4,942 5,448 5,957 6,4691,597 1,972 2,350

Page 14 - MYSON EZ-Hose Kit

MODEL UNIT PACKED# WEIGHT WEIGHTKickspace Heaters from MYSONWHISPA 50 FAN CONVECTOR — BTU/HR HEAT OUTPUT — ENTERING AIR @ 65°FKICKSPACE COMPARISON @

Page 15 - Optional Piping Arrangements

6 Myson, Inc. • 800-698-9690 • www.MysonInc.com14"151⁄2"1911⁄16"Power/Fan Settings:OFF ONIndicated by red light.Heater Settings:OFF LOW

Page 16 - The Limited Warranty

Myson, Inc. • 800-698-9690 • www.MysonInc.com 7Fan Convector from MYSONMODEL FLOW RATE FAN SPEED AIR DELIVERY#GPM1CFM6,940 8,569 10,213 11,870 13,538